OC Air Purifier 1000


Technical Data

Techdata_OCAP_2.png

LwA - sound power level (measured acc. to EN ISO 3741, EN ISO 5135)

LpA 1m - sound pressure level at distance 1 m from the unit (measured acc. to EN ISO 3741, EN ISO 5135)

LpA 3m - sound pressure level at distance 3 m from the unit (measured acc. to EN ISO 3741, EN ISO 5135)

I - electrical current at 230 V AC

P - electrical power



Air Purifier Efficiency

The mobile HEPA filter unit efficiency can be described as a timeline of particle concentration inside a room. Higher airflow rates enable quicker removal of moving particles inside a room. Two studies were performed on a typical open space with two particle types: aerosol and dust, which both can carry unwanted microbes and infectious agents.

#

The study was performed in a room with 10x10 m of floor area and a ceiling height of 3 m (total volume 300 m3). The unit was placed in the center of the room. Initial aerosol particles distribution was homogeneous in the whole room, and monitored as 100% particle concentration. Three different airflow settings were used to monitor the timeline of particle concentration in the room.

#

The study was perfomed in a room with 10x10 m of floor area and a ceiling height of 3 m (total volume 300 m3). The unit was placed in the center of the room. Initial dust particles were distributed on a horizontal surface inside the room (floor area and top surface of the unit), and monitored as 100% particle concentration. Three different airflow settings were used to monitor the timeline of particle concentration in the room.

Contact

In case of additional questions regarding technical characteristics or customized units please contact us